Register for a Trade Account

Products

4321 products

  • Victron Energy Shore Power Cord 25m 16A (3×2.5sqmm) – SHP302502500-Powerland

    Victron Victron Energy Shore Power Cord 25m 16A (3×2.5sqmm) – SHP302502500

      Brand Victron Energy Manufacturer Part Number SHP302502500 Current Rating (A) 16 Connector Type Moulded IEC 60309 3-Pole Cable Type H07BQ-F 3x 2,50mm² Plug Type Moulded IEC 60309 2p+E Cable Length 25m Weight (kg) 4.3 Warranty 5 Years Country of Manufacture Netherlands

    £158.20 Exc. VAT

    £189.84 Inc. VAT

  • Victron Energy Shore Power Cord 25m 32A (3x6sqmm) – SHP306002500-Powerland

    Victron Victron Energy Shore Power Cord 25m 32A (3x6sqmm) – SHP306002500

    Brand Victron Energy Manufacturer Part Number SHP306002500 Current Rating (A) 32 Connector Type Moulded IEC 60309 3-Pole Cable Type H07BQ-F 3x 4,00mm² Plug Type Moulded IEC 60309 2p+E Cable Length 25m Weight (kg) 7 Warranty 5 Years

    £292.60 Exc. VAT

    £351.12 Inc. VAT

  • Victron Energy Shunt 1000A/50mV-0.5 / 2xM10 – SHU102050200-Powerland

    Victron Victron Energy Shunt 1000A/50mV-0.5 / 2xM10 – SHU102050200

    Brand Victron Energy Manufacturer Part Number SHU102050200 Warranty 5 Years

    £68.34 Exc. VAT

    £82.01 Inc. VAT

  • Victron Energy Shunt 2000A/50mV-0,5 / 3xM10 – SHU202050200-Powerland

    Victron Victron Energy Shunt 2000A/50mV-0,5 / 3xM10 – SHU202050200

    Brand Victron Energy Manufacturer Part Number SHU102050200 Warranty 5 Years

    £81.20 Exc. VAT

    £97.44 Inc. VAT

  • Victron Energy Shunt 500A/50mV – SHU500050100-Powerland

    Victron Victron Energy Shunt 500A/50mV – SHU500050100

    Brand Victron Energy Manufacturer Part Number SHU500050100 Warranty 5 Years

    £20.84 Exc. VAT

    £25.01 Inc. VAT

  • Victron Energy Shunt 6000A/50mV – SHU602050200-Powerland

    Victron Victron Energy Shunt 6000A/50mV – SHU602050200

    Brand Victron Energy Manufacturer Part Number SHU602050200 Warranty 5 Years

    £188.34 Exc. VAT

    £226.01 Inc. VAT

  • Victron Energy Skylla Control CE – SDRPSKC-Powerland

    Victron Victron Energy Skylla Control CE – SDRPSKC

      Brand Victron Energy Manufacturer Part Number SDRPSKC Dimensions L120 x W65mm Weight (kg) 0.2 Warranty 5 Years

    £105.00 Exc. VAT

    £126.00 Inc. VAT

  • Victron Energy Skylla-i 24/100(1+1) – SKI024100000-Powerland

    Victron Victron Energy Skylla-i 24/100(1+1) – SKI024100000

    The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready   Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024100000 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Bolts Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years

    £939.40 Exc. VAT

    £1,127.28 Inc. VAT

  • Victron Energy Skylla-i 24/100(3) – SKI024100002-Powerland

    Victron Victron Energy Skylla-i 24/100(3) – SKI024100002

    The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready   Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024100002 Voltage 24 Charger Current House Battery 3 x 100A Charger Current Starter Battery N.A. Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Bolts Outputs 3 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years

    £1,101.10 Exc. VAT

    £1,321.32 Inc. VAT

  • Victron Energy Skylla-i 24/80(1+1) – SKI024080000-Powerland

    Victron Victron Energy Skylla-i 24/80(1+1) – SKI024080000

    The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready   Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024080000 Voltage 24 Charger Current House Battery 80A Charger Current Starter Battery 4A Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Bolts Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years

    £720.00 Exc. VAT

    £864.00 Inc. VAT

  • Victron Energy Skylla-i 24/80(3) – SKI024080002-Powerland

    Victron Victron Energy Skylla-i 24/80(3) – SKI024080002

    The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready  Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024080002 Voltage 24 Charger Current House Battery 3 x 80A Charger Current Starter Battery N.A. Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Bolts Outputs 3 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years

    £907.20 Exc. VAT

    £1,088.64 Inc. VAT

  • Victron Energy Skylla-i Control GX (Right Angle RJ45) – REC000300010R-Powerland

    £88.15 Exc. VAT

    £105.78 Inc. VAT

  • Victron Energy Skylla-i Remote On-Off Cable – ASS030550400-Powerland

    Victron Victron Energy Skylla-i Remote On-Off Cable – ASS030550400

    This cable is intended for on/off control of the Skylla-i when the source signal is high when the Skylla-i must be on, and low or free floating when Skylla-i must be off. Brand Victron Energy Manufacturer Part Number ASS030550400 Max. Input Voltage 70V Warranty 5 Years

    £15.00 Exc. VAT

    £18.00 Inc. VAT

  • Victron Energy Skylla-IP65 12/70(1+1) – SKY012070000-Powerland

    Victron Victron Energy Skylla-IP65 12/70(1+1) – SKY012070000

    The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (1+1): two outputs to charge 2 battery banks The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY012070000 GTIN 8719076051961 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 VAC 12A Charge current 70A Charge Algorithm 7 stage adaptive Battery Capacity 350-700Ah Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off port Yes (can be connected to a Li-Ion BMS) Battery-Connection M6 bolts 230 VAC-connection Screw-clamp 6mm² (AWG 10) Protection Category IP65 Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years

    £511.70 Exc. VAT

    £614.04 Inc. VAT

  • Victron Energy Skylla-IP65 12/70(3) 120-240V – SKY012070100-Powerland

    Victron Victron Energy Skylla-IP65 12/70(3) 120-240V – SKY012070100

    The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (3): three full current outputs to charge 3 battery banks The Skylla-IP65 (3) features 3 isolated outputs. All outputs can supply the full rated output current. IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY012070100 GTIN 8719076051978 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 3 x 70A Charge current starter batt. n.a Charge Algorithm 7 stage adaptive Battery Capacity 350-700Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years

    £564.20 Exc. VAT

    £677.04 Inc. VAT

  • Victron Energy Skylla-IP65 24/35(1+1) 120-240V – SKY024035000-Powerland

    Victron Victron Energy Skylla-IP65 24/35(1+1) 120-240V – SKY024035000

    The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air.  Features Skylla-IP65 (1+1): two outputs to charge 2 battery banks The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY024035000 GTIN 8719076051985 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 35A Charge current starter batt. 3A Charge Algorithm 7 stage adaptive Battery Capacity 150-350Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years

    £529.90 Exc. VAT

    £635.88 Inc. VAT

  • Victron Energy Skylla-IP65 24/35(3) 120-240V – SKY024035100-Powerland

    Victron Victron Energy Skylla-IP65 24/35(3) 120-240V – SKY024035100

    The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (3): three full current outputs to charge 3 battery banks The Skylla-IP65 (3) features 3 isolated outputs. All outputs can supply the full rated output current. IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY024035100 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 3 x 35A Charge current starter batt. n.a Charge Algorithm 7 stage adaptive Battery Capacity 150-350Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years Country of Manufacture Malaysia

    £549.90 Exc. VAT

    £659.88 Inc. VAT

  • Victron Energy Skylla-TG 24/100(1+1) 3 Phase – STG024100300-Powerland

    Victron Victron Energy Skylla-TG 24/100(1+1) 3 Phase – STG024100300

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number STG024100300 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H515 x W260 x D265mm Weight (kg) 23 Warranty 5 Years

    £1,330.80 Exc. VAT

    £1,596.96 Inc. VAT

  • Victron Energy Skylla-TG 24/100(1+1) GL – SDTG2401003-Powerland

    Victron Victron Energy Skylla-TG 24/100(1+1) GL – SDTG2401003

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2401003 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years

    £1,195.60 Exc. VAT

    £1,434.72 Inc. VAT

  • Victron Energy Skylla-TG 24/100(1+1) – SDTG2401001-Powerland

    Victron Victron Energy Skylla-TG 24/100(1+1) – SDTG2401001

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2401001 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years

    £980.70 Exc. VAT

    £1,176.84 Inc. VAT

  • Victron Energy Skylla-TG 24/30 GMDSS – SDTG2400302-Powerland

    Victron Victron Energy Skylla-TG 24/30 GMDSS – SDTG2400302

    Features GMDSS The Global Maritime Distress & Safety System (GMDSS) was developed by the International Maritime Organisation (IMO) to improve maritime distress and safety communications. Power supply The Skylla TG has proven itself to be an excellent battery charger and power supply for GMDSS applications. However, when using a standard Skylla Charger, additional equipment is needed to perform the monitoring and alarm functions required for GMDSS. Installation made easy: the Skylla GMDSS The Victron Skylla GMDSS Charger has been designed to provide all required monitoring and alarm data. Both the battery and the GMDSS system are connected directly to the charger. Data and alarms are displayed on a digital panel (VE.Net GMDSS panel, to be ordered separately). A standard eight wire UTP-cable connects the charger to the panel. No adjustments needed The whole system is ‘click and go’: the panels are pre-programmed for GMDSS functionality. A simple, intuitive menu allows changing of settings if required. Battery time to go The Skylla GMDSS charger has a built-in battery controller. The capacity of the battery is fully monitored so the panel can even indicate the ’time to go’ in case of a power supply black out. Perfect charger for any type of battery Charge voltage can be precisely adjusted to suit any VRLA or flooded battery system Brand Victron Energy Manufacturer Part Number SDTG2400302 Voltage 24 Charge Current (A) 30 (limited to 22A at 110VAC) Input Voltage 230VAC Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H485 x W250 x D147mm Weight (kg) 6 Warranty 5 Years

    £646.89 Exc. VAT

    £776.27 Inc. VAT

  • Victron Energy Skylla-TG 24/30(1+1) GL – SDTG2400303-Powerland

    Victron Victron Energy Skylla-TG 24/30(1+1) GL – SDTG2400303

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400303 Voltage 24 Charger Current House Battery 30A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 300Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x D250 x D147mm Weight (kg) 5.5 Warranty 5 Years

    £520.90 Exc. VAT

    £625.08 Inc. VAT

  • Victron Energy Skylla-TG 24/30(1+1) – SDTG2400301-Powerland

    Victron Victron Energy Skylla-TG 24/30(1+1) – SDTG2400301

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400301 Voltage 24 Charger Current House Battery 30A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years

    £457.80 Exc. VAT

    £549.36 Inc. VAT

  • Victron Energy Skylla-TG 24/50 GMDSS – SDTG2400504-Powerland

    Victron Victron Energy Skylla-TG 24/50 GMDSS – SDTG2400504

    Features GMDSS The Global Maritime Distress & Safety System (GMDSS) was developed by the International Maritime Organisation (IMO) to improve maritime distress and safety communications. Power supply The Skylla TG has proven itself to be an excellent battery charger and power supply for GMDSS applications. However, when using a standard Skylla Charger, additional equipment is needed to perform the monitoring and alarm functions required for GMDSS. Installation made easy: the Skylla GMDSS The Victron Skylla GMDSS Charger has been designed to provide all required monitoring and alarm data. Both the battery and the GMDSS system are connected directly to the charger. Data and alarms are displayed on a digital panel (VE.Net GMDSS panel, to be ordered separately). A standard eight wire UTP-cable connects the charger to the panel. No adjustments needed The whole system is ‘click and go’: the panels are pre-programmed for GMDSS functionality. A simple, intuitive menu allows changing of settings if required. Battery time to go The Skylla GMDSS charger has a built-in battery controller. The capacity of the battery is fully monitored so the panel can even indicate the ’time to go’ in case of a power supply black out. Perfect charger for any type of battery Charge voltage can be precisely adjusted to suit any VRLA or flooded battery system Brand Victron Energy Manufacturer Part Number SDTG2400302 Voltage 24 Charge Current (A) 30 (limited to 22A at 110VAC) Input Voltage 230VAC Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H485 x W250 x D147mm Weight (kg) 6 Warranty 5 Years

    £813.13 Exc. VAT

    £975.76 Inc. VAT

  • Victron Energy Skylla-TG 24/50(1+1) 3 Phase – STG024050300-Powerland

    Victron Victron Energy Skylla-TG 24/50(1+1) 3 Phase – STG024050300

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number STG024050300 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 13 Warranty 5 Years

    £831.88 Exc. VAT

    £998.26 Inc. VAT

  • Victron Energy Skylla-TG 24/50(1+1) GL – SDTG2400503-Powerland

    Victron Victron Energy Skylla-TG 24/50(1+1) GL – SDTG2400503

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.   Brand Victron Energy Manufacturer Part Number SDTG2400503 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x D250 x 147mm Weight (kg) 5.5 Warranty 5 Years

    £578.75 Exc. VAT

    £694.50 Inc. VAT

  • Victron Energy Skylla-TG 24/50(1+1) – SDTG2400501-Powerland

    Victron Victron Energy Skylla-TG 24/50(1+1) – SDTG2400501

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400501 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years Country of Manufacture Malaysia

    £483.44 Exc. VAT

    £580.13 Inc. VAT

  • Victron Energy Skylla-TG 24/80(1+1) – SDTG2400801-Powerland

    Victron Victron Energy Skylla-TG 24/80(1+1) – SDTG2400801

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400801 Voltage 24 Charger Current House Battery 80A Charger Current Starter Battery 4A Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years

    £812.70 Exc. VAT

    £975.24 Inc. VAT

  • Victron Energy Skylla-TG 48/25(1) – SDTG4800251-Powerland

    Victron Victron Energy Skylla-TG 48/25(1) – SDTG4800251

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG4800251 Voltage 48 Charger Current House Battery 25A Charger Current Starter Battery N.A. Recommended Battery Capacity 125 – 250Ah Battery Connection M8 Studs Outputs 1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years  

    £550.20 Exc. VAT

    £660.24 Inc. VAT

  • Victron Energy Skylla-TG 48/50(1) – SDTG4800501-Powerland

    Victron Victron Energy Skylla-TG 48/50(1) – SDTG4800501

    Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG4800501 Voltage 48 Charger Current House Battery 50A Charger Current Starter Battery N.A. Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years

    £1,057.70 Exc. VAT

    £1,269.24 Inc. VAT

  • Victron Energy Smart Battery Protect 12/24V 100A – BPR110022000-Powerland

    Victron Victron Energy Smart Battery Protect 12/24V 100A – BPR110022000

    When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).  If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources. Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.   Brand Victron Energy Manufacturer Part Number BPR065022000 Voltage 12/24 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 65A Connection M6 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H40 x W48 x D106mm Weight (kg) 0.2 Warranty 5 Years

    £61.67 Exc. VAT

    £74.00 Inc. VAT

  • Victron Energy Smart Battery Protect 12/24V 220A – BPR122022000-Powerland

    Victron Victron Energy Smart Battery Protect 12/24V 220A – BPR122022000

    When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).  If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources.   Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR122022000 Voltage 12/24 Peak Current (During 30 Seconds) 600A Max. Continuous Load Current 200A Connection M8 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H62 x 123 x D120 Weight (kg) 0.8 Warranty 5 Years

    £92.49 Exc. VAT

    £110.99 Inc. VAT

  • Victron Energy Smart Battery Protect 12/24V 65A – BPR065022000-Powerland

    Victron Victron Energy Smart Battery Protect 12/24V 65A – BPR065022000

    When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).  If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources.   Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR065022000 Voltage 12/24 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 65A Connection M6 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H40 x W48 x D106mm Weight (kg) 0.2 Warranty 5 Years

    £37.50 Exc. VAT

    £45.00 Inc. VAT

  • Victron Energy Smart Battery Protect 48V 100A – BPR110048000-Powerland

    Victron Victron Energy Smart Battery Protect 48V 100A – BPR110048000

    When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).  If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources.   Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR110048000 Voltage 48 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 100A Connection M8 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H62 x W123 x D120mm Weight (kg) 0.8 Warranty 5 Years

    £83.80 Exc. VAT

    £100.56 Inc. VAT

  • Victron Energy Smart Battery Sense Long Range 10-meters for MPPT Solar Chargers – SBS050150200-Powerland

    Victron Victron Energy Smart Battery Sense Long Range 10-meters for MPPT Solar Chargers – SBS050150200

    Improves battery charging By measuring voltage at the battery bank terminals, errors arising from voltage-loss due to cable resistance are avoided – guaranteeing the correct charge-voltage. For lead batteries, battery temperature data is used to adjust the charge-voltages: cold batteries require an increased charge-voltage, whereas hot batteries require a decreased charge-voltage. For lithium batteries temperature data is used to disable charging when they are too cold: charging lithium batteries near or below freezing causes permanent damage to the cells. Look no wires The connection between Smart Battery Sense and one or more Solar Charger(s) is wireless: It uses VE.Smart Network – a wireless technology based on Bluetooth Smart. Information transmitted can be used simultaneously by one, two or more Solar Chargers connected to the same 12V, 24V and 48V battery bank. The Smart Network is set up using the VictronConnect app. Tidy, simple – smart Installation is simple, quick and tidy. Just connect the unit’s two eyelets to your battery terminals and attach the Smart Battery Sense unit directly onto the battery-body using its self-adhesive strip. Brand Victron Energy Manufacturer Part Number SBS050150200 Operating Voltage Range 8-60V Absolute Maximum Voltage 65V Cable Length 45cm Dimensions H14 x W38 x D38mm Warranty 5 Years

    £26.00 Exc. VAT

    £31.20 Inc. VAT

  • Victron Energy Smart BMS 12/200 – BMS210055000-Powerland

    Victron Victron Energy Smart BMS 12/200 – BMS210055000

    It combines a Current Limiter, Battery Combiner and Battery Protector in a robust and compact solution and lets you safely connect any size 12V alternator (and starter battery), loads and chargers to Smart Lithium batteries. The Smart BMS 12/200 monitors and protects each individual battery cell within the battery (or battery bank) and will disconnect the alternator, charge sources or DC loads in case of low battery cell voltage, high battery cell voltage or over temperature. The dedicated alternator connection provides current limiting and one-way traffic from the alternator into the battery, this so any size alternator (and starter battery) can be safely connected to the Smart Lithium battery (or battery bank) and the starter battery is protected from excessive discharge. The BMS is equipped with Bluetooth for monitoring and configuration, a remote on/off connector, to turn the BMS (and the system) off via a remote switch and a pre-alarm contact, to give a warning signal before the BMS will disconnect the batteries from the system.   Features Battery Management system The BMS connects to 12,8V Victron LiFePO4 (LFP) batteries. Up to 5 batteries may be connected in parallel. Can be used as a system on/off switch. Starter battery Protection This function is similar to that of a Cyrix Battery Combiner or Argo FET Battery Isolator. Current can flow to the LFP battery only if the input voltage (= voltage on the starter battery) exceeds 13V. Additionaly current cannot flow back from the LFP battery to the starter battery, thus preventing eventual damage to the LFP battery due to excessive discharge. Alternator and battery protection The input current is electronically limited to approximately 90% of the fuse rating. A 100A fuse, for example, will therefore limit the input current to approximately 90A. Choosing the right fuse will: a. Protect the LFP battery against excessive charge current (important in case of a low capacity LFP battery). b. Protect the alternator against overload in case of a high capacity LFP battery bank (most 12V alternators will overheat and fail if running at maximum output during more than 5 minutes). Load/battery charger output-input (Power Port SYSTEM+) This Power Port can be used to either charge or discharge the LFP battery (i.e. via a charger, an inverter or inverter/charger) with a maximum continuous current of 200A in both directions. Can also be used as a load output, thus DC loads can be connected directly to this port. The port is short-circuit protected with a peak discharge current of 400A. The Smart BMS will make sure that the battery discharge will cut-off in case of imminent cell under voltage. The Smart BMS will enable charging through this port, but no charge algorithm can be applied internally. Li-ion battery protection Excessive input voltage and transients are regulated down to a safe level. The Smart BMS will stop charging in case of cell over voltage or over temperature. It has three outputs, similar to the smallBMS: Load Disconnect output The Load output is normally high and becomes free floating in case of imminent cell under voltage (default 2,8V/cell, adjustable on the battery between 2,6V and 2,8V per cell). Maximum current: 10mA. The Load output can be used to control the remote on/off input of a Battery Protect, inverter, DC-DC converter or other loads. Pre-Alarm output The pre-alarm output can be used as warning when the battery voltage is low and it will trip shortly before the Load Disconnect output is disabled due to cell under voltage. The pre-alarm output may be used to drive a relay, LED or Buzzer. It can be configured as continuous or intermittent signal. The pre-alarm output is normally free floating and becomes high in case of imminent cell under voltage (default 3,1V/cell, adjustable on the battery between 2,85V and 3,15V per cell). Maximum current: 1A (not short circuit protected) The minimum delay between pre-alarm and load disconnect is 30 seconds. Charge disconnect output The Charge disconnect output is normally high and becomes free floating in case of imminent cell over voltage or over temperature. Maximum current: 10mA. The Charge disconnect output is not suitable to power an inductive load such as a relay coil. The Charge disconnect output can be used to control: the remote on/off of a charger, a Cyrix-Li-Charge relay, a Cyrix-Li-ct Battery Combiner. (Note: in some cases an interface cable will be needed, please see the manual.) Remote on/off input The remote on/off input controls the charging via the alternator. When off, charging via the alternator is disabled, while the BMS functionality will remain active allowing any loads and chargers to continue working regardless of the state of the remote input. When “system on/off switch” is enabled via VictronConnect, the BMS functionality will also be disabled. It consists of two terminals: Remote L and Remote H. A remote on-off switch or relay contact can be connected between H and L. Alternatively, terminal H can be switched to battery plus, or terminal L can be switched to battery minus Ignition proof No relays but MOSFET switches, and therefore, no sparks. Maximum continuous charge current 100A (with 125A fuse) DC power connection M8 DC connector battery minus Faston female, 6.3mm Maximum discharge current, Port SYSTEM+ 200A Maximum charge current, Port SYSTEM+ 200A Current consumption, remote off 5mA (BMS functionality active) Current consumption, no load operation 16mA (excluding Load output and Charge output current) Peak discharge current 400A Protection grade IP65

    £164.75 Exc. VAT

    £197.70 Inc. VAT

  • Victron Energy Smart BMS CL 12/100 – BMS110022000-Powerland

    Victron Victron Energy Smart BMS CL 12/100 – BMS110022000

    The BMS CL 12/100 monitors and protects each individual battery cell within the battery (or battery bank) and will disconnect the alternator, charge sources or DC loads in case of low battery voltage, high battery voltage or over temperature. The dedicated alternator input provides current limiting and one-way traffic from the alternator into the battery, this so any size alternator (and start battery) can be safely connected to the Smart Lithium battery or batteries. The BMS is also equipped with a remote on off connector, to turn the BMS (and the system) off via a remote switch, and a pre-alarm contact, to give a warning signal before the BMS will disconnect the batteries from the system.   Features Battery Management system The BMS connects to 12,8V Victron LiFePO4 (LFP) batteries. Up to 5 batteries may be connected in parallel. Can be used as a system on/off switch. Alternator and battery protection The input current is electronically limited to approximately 90% of the fuse rating. A 100A fuse, for example, will therefore limit the input current to approximately 90A. Choosing the right fuse will: a. Protect the LFP battery against excessive charge current (important in case of a low capacity LFP battery). b. Protect the alternator against overload in case of a high capacity LFP battery bank (most 12V alternators will overheat and fail if running at maximum output during more than 5 minutes). Starter battery Protection This function is similar to that of a Cyrix Battery Combiner or Argo FET Battery Isolator. Current can flow to the LFP battery only if the input voltage (= voltage on the starter battery) exceeds 13V. And current cannot flow back from the LFP battery to the starter battery, thus preventing eventual damage to the LFP battery due to excessive discharge. Li-ion battery protection Excessive input voltage and transients are regulated down to a safe level. The Smart BMS CL will stop charging in case of cell over voltage or over temperature. It has three outputs, similar to the miniBMS Remote on/off input The remote on/off input controls the charging via the alternator. When off, charging via the alternator is disabled, while the BMS functionality will remain active allowing any loads and chargers to continue working regardless of the state of the remote input. When “system on/off switch” is enabled via VictronConnect, the BMS functionality will also be disabled. It consists of two terminals: Remote L and Remote H. A remote on-off switch or relay contact can be connected between H and L. Alternatively, terminal H can be switched to battery plus, or terminal L can be switched to battery minus Ignition proof No relays but MOSFET switches, and therefore no sparks. Brand Victron Energy Manufacturer Part Number BMS110022000 Maximum continuous charge current 100A (with 125A fuse) Input voltage to start charging > 13V Operating temperature range -40°C to +60°C Protection Category IP65 DC power connection M8 DC connector battery minus Faston female, 6.3mm Dimensions H65 x W120 x D224mm Weight 1.6Kg Warranty 5 Years

    £104.16 Exc. VAT

    £124.99 Inc. VAT

  • Victron Energy SmartShunt 1000A/50mV – SHU050210050-Powerland

    Victron Victron Energy SmartShunt 1000A/50mV – SHU050210050

    The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted. The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV712 Battery Monitor No programmable visual and audible alarm. No programmable relay.   Brand Victron Energy Manufacturer Part Number SHU050210050 Supply Voltage Range 6.5-70VDC Battery Capacity 1-9999Ah VE.Direct Communication Port Yes Protection Category IP21 Dimensions H68 x W120 x D54mm Warranty 5 Years

    £99.00 Exc. VAT

    £118.80 Inc. VAT

  • Victron Energy SmartShunt 2000A/50mV – SHU050220050-Powerland

    Victron Victron Energy SmartShunt 2000A/50mV – SHU050220050

    The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted. The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV712 Battery Monitor No programmable visual and audible alarm. No programmable relay. Brand Victron Energy Manufacturer Part Number SHU050220050 Supply Voltage Range 6.5-70VDC Battery Capacity 1-9999Ah VE.Direct Communication Port Yes Protection Category IP21 Dimensions H68 x W120 x D76mm Warranty 5 Years

    £144.97 Exc. VAT

    £173.96 Inc. VAT

  • Victron Energy SmartShunt 300A

    Victron Victron Energy SmartShunt 300A

    The SmartShunt connects via Bluetooth to the VictronConnect App. The VictronConnect App is used to read out all monitored battery parameters and is also used to make or change settings. Alternatively, the SmartShunt can connect to a GX device, like the ColorControl GX or the Cerbo GX. The SmartShunt has an auxiliary input that can be used to monitor the voltage of a second battery or to monitor the midpoint of a battery bank. The auxiliary input can also be used for battery temperature monitoring together with the optional Temperature sensor for BMV. TECHNICAL SPECIFICATION SmartShunt – 300A Supply voltage range – 6.5 – 70 VDC Current draw – < 1mA Input voltage range, auxiliary battery – 6.5 – 70 VDC Battery capacity (Ah) – 1 – 9999 Ah Operating temperature range – -40 +50°C (-40 – 120°F) Measures voltage of second battery, or temperature, or midpoint – Yes Temperature measurement range – -20 +50°C VE.Direct communication port – Yes RESOLUTION & ACCURACY Current – ± 0.01 A Voltage – ± 0.01 V Amp hours – ± 0.1 Ah State of charge (0 – 100 %) – ± 0.1 % Time to go – ± 1 min Temperature (if optional temperature sensor connected) – ± 1 °C/°F (0 – 50 °C or 30 – 120 °F) Accuracy of current measurement – ± 0.4 % Offset – Less than 20 / 40 / 80 mA Accuracy of voltage measurement – ± 0.3 % INSTALLATION & DIMENSIONS Dimensions (h x w x d) – 300 A: 44 x 120 x 44 mm Shunt connection bolts – M8 (0.3937 inch) Protection category – IP21 Part number – SHU050130050 Brand Victron Energy Manufacturer Part Number SHU050130050 Supply Voltage Range 6.5 – 70 VDC Operating Temperature -40 +50°C (-40 – 120°F) Current ± 0.01 A

    £49.17 Exc. VAT

    £59.00 Inc. VAT

  • Victron Energy SmartShunt 500A/50mV – SHU050150050-Powerland

    Victron Victron Energy SmartShunt 500A/50mV – SHU050150050

    The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted. The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV712 Battery Monitor No programmable visual and audible alarm. No programmable relay. Brand Victron Energy Manufacturer Part Number SHU050150050 Supply Voltage Range 6.5-70VDC Battery Capacity 1-9999Ah VE.Direct Communication Port Yes Protection Category IP21 Dimensions H46 x W120 x D54mm Warranty 5 Years

    £61.67 Exc. VAT

    £74.00 Inc. VAT

  • Victron Energy SmartShunt IP65 1000A – SHU065210050-Powerland

    Victron Victron Energy SmartShunt IP65 1000A – SHU065210050

    The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted.The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV-712 Battery Monitor– No programmable visual and audible alarm– No programmable relay Why should I monitor my battery with the SmartShunt IP65 1000A?Batteries are used in a wide variety of applications, mostly to store energy for later use. But how much energy is stored in the battery? No one can tell by just looking at it. The service life of batteries depends on many factors. Battery life may be shortened by under-charging, over-charging, excessively deep discharges, excessive charge or discharge currents, and by high ambient temperature. Monitoring the battery with a battery monitor will give important feedback to the user so that remedial measures can be taken when necessary. Doing this will extend battery life and the battery monitor will quickly pay for itself.   Brand Victron Energy Manufacturer Part Number SHU065210050 gtin 8719076057901 Protection Category IP65 Bluetooth Enabled Yes Dimensions H68 x W168 x D75mm Country of Manufacture India Warranty 5 Years

    £153.34 Exc. VAT

    £184.01 Inc. VAT

  • Victron Energy SmartShunt IP65 2000A – SHU065220050-Powerland

    Victron Victron Energy SmartShunt IP65 2000A – SHU065220050

    The SmartShunt is a good alternative for a BMV battery monitor, especially for systems where battery monitoring is needed but less wiring and clutter is wanted.The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV-712 Battery Monitor– No programmable visual and audible alarm– No programmable relay Why should I monitor my battery with the SmartShunt IP65 2000A?Batteries are used in a wide variety of applications, mostly to store energy for later use. But how much energy is stored in the battery? No one can tell by just looking at it. The service life of batteries depends on many factors. Battery life may be shortened by under-charging, over-charging, excessively deep discharges, excessive charge or discharge currents, and by high ambient temperature. Monitoring the battery with a battery monitor will give important feedback to the user so that remedial measures can be taken when necessary. Doing this will extend battery life and the battery monitor will quickly pay for itself.   Brand Victron Energy Manufacturer Part Number SHU065220050 gtin 8719076057918 Protection Category IP65 Bluetooth Enabled Yes Dimensions H68 x W168 x D100mm Warranty 5 Years Country of Manufacture India

    £144.96 Exc. VAT

    £173.95 Inc. VAT

  • Victron Energy SmartShunt IP65 500A – SHU065150050-Powerland

    Victron Victron Energy SmartShunt IP65 500A – SHU065150050

    The SmartShunt is a good alternative for a BMV battery monitor especially for systems where battery monitoring is needed but less wiring and clutter is wanted.The SmartShunt is equipped with Bluetooth, a VE.Direct port and a connection that can be used for: monitoring a second battery, midpoint monitoring or a temperature sensor. Differences compared to BMV-712 Battery Monitor– No programmable visual and audible alarm– No programmable relay Why should I monitor my battery with the SmartShunt IP65 500A?Batteries are used in a wide variety of applications, mostly to store energy for later use. But how much energy is stored in the battery? No one can tell by just looking at it. The service life of batteries depends on many factors. Battery life may be shortened by under-charging, over-charging, excessively deep discharges, excessive charge or discharge currents, and by high ambient temperature. Monitoring the battery with a battery monitor will give important feedback to the user so that remedial measures can be taken when necessary. Doing this will extend battery life and the battery monitor will quickly pay for itself. Brand Victron Energy Manufacturer Part Number SHU065150050 gtin 8719076057895 Protection Category IP65 Bluetooth Enabled Yes Dimensions H46 x W120 x D54mm Warranty 5 Years Country of Manufacture India

    £92.50 Exc. VAT

    £111.00 Inc. VAT

  • Victron Energy SmartSolar MPPT 100/15 – SCC110015060R-Powerland

    Victron Victron Energy SmartSolar MPPT 100/15 – SCC110015060R

    MPPT: Ultra Fast Maximum Power Point Tracking By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing. Remote Monitoring and Control Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in bluetooth by pairing it with your smartphone or other device via VictronConnect. If your installation is connected to the internet Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both services are free to use. For remote installations – even when there is no internet connection or phone signal nearby – you may be able to monitor your MPPT by bluetooth-pairing with a LoRaWAN (long-range wide area network) device, available optionally. Load output The intelligent Load output function prevents damage caused by running batteries ‘flat’. You can configure the voltage at which SmartSolar disconnects a load – thereby preventing excessive drain on your batteries. And here’s the clever bit: SmartSolar will attempt a 100% recharge every day. If it can’t – during periods of poor weather – it raises the disconnect voltage, daily, until it achieves success. We call this feature BatteryLife because it maintains the health, and extends the life of your battery. Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices Battery Life: intelligent battery management When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards, the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week. Internal temperature sensor Compensates absorption and float charge voltage for temperature. Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers. Brand Victron Energy Manufacturer Part Number SCC110015060R GTIN 8719076040811 Battery Voltage 12/24 Auto Select Rated Charge Current 15A Nominal PV Power, 12V 220W Nominal PV Power, 24V 440W Max. PV Short Circuit Current 15A Maximum PV Open Circuit Voltage 100V Efficiency 98% Charge Algorithm Multi-stage adaptive Data Communication Port VE.Direct IP Rating IP43 (electronic components), IP22 (connection area) Dimensions H100 x W113 x D50mm Weight 0.6Kg Warranty 5 Years

    £45.00 Exc. VAT

    £54.00 Inc. VAT

  • Victron Energy SmartSolar MPPT 100/20 48V – SCC110020160R-Powerland

    Victron Victron Energy SmartSolar MPPT 100/20 48V – SCC110020160R

    MPPT: Ultra Fast Maximum Power Point Tracking By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing. Remote Monitoring and Control Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in bluetooth by pairing it with your smartphone or other device via VictronConnect. If your installation is connected to the internet Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both services are free to use. For remote installations – even when there is no internet connection or phone signal nearby – you may be able to monitor your MPPT by bluetooth-pairing with a LoRaWAN (long-range wide area network) device, available optionally. Load output The intelligent Load output function prevents damage caused by running batteries ‘flat’. You can configure the voltage at which SmartSolar disconnects a load – thereby preventing excessive drain on your batteries. And here’s the clever bit: SmartSolar will attempt a 100% recharge every day. If it can’t – during periods of poor weather – it raises the disconnect voltage, daily, until it achieves success. We call this feature BatteryLife because it maintains the health, and extends the life of your battery. Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices Battery Life: intelligent battery management When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards, the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week. Internal temperature sensor Compensates absorption and float charge voltage for temperature. Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers. Brand Victron Energy Manufacturer Part Number SCC110020160R GTIN 8719076043027 Battery Voltage 48V Rated Charge Current 20A Nominal PV Power, 12V 290W Nominal PV Power, 24V 580W Nominal PV Power, 48V 1160W Max. PV Short Circuit Current 20A Maximum PV Open Circuit Voltage 100V Efficiency 98% Charge Algorithm Multi-stage adaptive Data Communication Port VE.Direct IP Rating IP43 (electronic components), IP22 (connection area) Dimensions H100 x W113 x D60mm Weight 0.65Kg Warranty 5 Years

    £52.00 Exc. VAT

    £62.40 Inc. VAT

  • Victron Energy SmartSolar MPPT 100/30 – SCC110030210-Powerland

    Victron Victron Energy SmartSolar MPPT 100/30 – SCC110030210

    MPPT: Ultra Fast Maximum Power Point Tracking By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing. Remote Monitoring and Control Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in bluetooth by pairing it with your smartphone or other device via VictronConnect. If your installation is connected to the internet Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both services are free to use. For remote installations – even when there is no internet connection or phone signal nearby – you may be able to monitor your MPPT by bluetooth-pairing with a LoRaWAN (long-range wide area network) device, available optionally. Load output The intelligent Load output function prevents damage caused by running batteries ‘flat’. You can configure the voltage at which SmartSolar disconnects a load – thereby preventing excessive drain on your batteries. And here’s the clever bit: SmartSolar will attempt a 100% recharge every day. If it can’t – during periods of poor weather – it raises the disconnect voltage, daily, until it achieves success. We call this feature BatteryLife because it maintains the health, and extends the life of your battery. Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices Advanced Maximum Power Point Detection in case of partial shading conditions If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP. Outstanding conversion efficiency No cooling fan. Maximum efficiency exceeds 98%. The full output current up to 40°C (104°F). Flexible charge algorithm Fully programmable charge algorithm (see the software page on our website), and eight pre-programmed algorithms, selectable with a rotary switch (see manual for details). Extensive electronic protection Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. PV reverse current protection. Internal temperature sensor Compensates absorption and float charge voltage for temperature. Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.   Brand Victron Energy Manufacturer Part Number SCC110030210 GTIN 8719076040170 Battery Voltage 12/24V Auto Select Rated Charge Current 30A Nominal PV Power, 12V 440W Nominal PV Power, 24V 880W Max. PV Short Circuit Current 35A Maximum PV Open Circuit Voltage 100V Efficiency 98% Charge Algorithm Multi-stage adaptive Data Communication Port VE.Direct IP Rating IP43 (electronic components), IP22 (connection area) Dimensions H130 x W186 x D70mm Weight 1.3Kg Warranty 5 Years

    £187.20£75.00 Exc. VAT

    £90.00 Inc. VAT

  • Victron Energy SmartSolar MPPT 100/50 – SCC110050210-Powerland

    Victron Victron Energy SmartSolar MPPT 100/50 – SCC110050210

    Features Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices Ultrafast Maximum Power Point Tracking (MPPT) Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers. Advanced Maximum Power Point Detection in case of partial shading conditions If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP. Outstanding conversion efficiency No cooling fan. Maximum efficiency exceeds 98%. The full output current up to 40°C (104°F). Flexible charge algorithm Fully programmable charge algorithm (see the software page on Victron), and eight pre-programmed algorithms, selectable with a rotary switch (see manual for details). Extensive electronic protection Over-temperature protection and power derating when temperature is high. PV short circuit and PV reverse polarity protection. PV reverse current protection. Internal temperature sensor Compensates absorption and float charge voltage for temperature. Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers. Fully discharged battery recovery function Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with integrated disconnect function. Brand Victron Energy Manufacturer Part Number SCC110050210 Battery Voltage 12/24V Auto Select Rated Charge Current 50A Nominal PV Power, 12V 700W Nominal PV Power, 24V 1400W Max. PV Short Circuit Current 60A Maximum PV Open Circuit Voltage 100V Efficiency 98% Charge Algorithm Multi-stage adaptive Data Communication Port VE.Direct IP Rating IP43 (electronic components), IP22 (connection area) Dimensions H130 x W186 x D70mm Weight (kg) 1.3 Warranty 5 Years

    £107.00 Exc. VAT

    £128.40 Inc. VAT

Forgot Password


Back to top