Powerland is a proud dealer of Victron Energy products, offering a comprehensive selection for off-grid, marine, and mobile applications. From inverters to solar chargers, Victron is known for its reliability and innovation.
Victron
Victron Victron Energy Smart Battery Protect 12/24V 65A – BPR065022000
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources. Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR065022000 Voltage 12/24 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 65A Connection M6 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H40 x W48 x D106mm Weight (kg) 0.2 Warranty 5 Years
£37.50 Exc. VAT
£45.00 Inc. VAT
Victron Victron Energy SmartShunt 300A
The SmartShunt connects via Bluetooth to the VictronConnect App. The VictronConnect App is used to read out all monitored battery parameters and is also used to make or change settings. Alternatively, the SmartShunt can connect to a GX device, like the ColorControl GX or the Cerbo GX. The SmartShunt has an auxiliary input that can be used to monitor the voltage of a second battery or to monitor the midpoint of a battery bank. The auxiliary input can also be used for battery temperature monitoring together with the optional Temperature sensor for BMV. TECHNICAL SPECIFICATION SmartShunt – 300A Supply voltage range – 6.5 – 70 VDC Current draw – < 1mA Input voltage range, auxiliary battery – 6.5 – 70 VDC Battery capacity (Ah) – 1 – 9999 Ah Operating temperature range – -40 +50°C (-40 – 120°F) Measures voltage of second battery, or temperature, or midpoint – Yes Temperature measurement range – -20 +50°C VE.Direct communication port – Yes RESOLUTION & ACCURACY Current – ± 0.01 A Voltage – ± 0.01 V Amp hours – ± 0.1 Ah State of charge (0 – 100 %) – ± 0.1 % Time to go – ± 1 min Temperature (if optional temperature sensor connected) – ± 1 °C/°F (0 – 50 °C or 30 – 120 °F) Accuracy of current measurement – ± 0.4 % Offset – Less than 20 / 40 / 80 mA Accuracy of voltage measurement – ± 0.3 % INSTALLATION & DIMENSIONS Dimensions (h x w x d) – 300 A: 44 x 120 x 44 mm Shunt connection bolts – M8 (0.3937 inch) Protection category – IP21 Part number – SHU050130050 Brand Victron Energy Manufacturer Part Number SHU050130050 Supply Voltage Range 6.5 – 70 VDC Operating Temperature -40 +50°C (-40 – 120°F) Current ± 0.01 A
£49.17 Exc. VAT
£59.00 Inc. VAT
Victron Victron Energy Smart Battery Protect 12/24V 100A – BPR110022000
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources. Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR065022000 Voltage 12/24 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 65A Connection M6 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H40 x W48 x D106mm Weight (kg) 0.2 Warranty 5 Years
£61.67 Exc. VAT
£74.00 Inc. VAT
Victron Victron Energy Smart Battery Protect 48V 100A – BPR110048000
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources. Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR110048000 Voltage 48 Peak Current (During 30 Seconds) 250A Max. Continuous Load Current 100A Connection M8 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H62 x W123 x D120mm Weight (kg) 0.8 Warranty 5 Years
£83.80 Exc. VAT
£100.56 Inc. VAT
Victron Victron Energy Smart Battery Protect 12/24V 220A – BPR122022000
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. The Smart BatteryProtect is not designed for reverse currents from charging sources. Features Protects the battery against excessive discharge and can be used as a system on/off switch The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch. 12/24V auto ranging The Smart BatteryProtect automatically detects system voltage one time only. Bluetooth: programming made easy When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled. A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS Ultra-low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Brand Victron Energy Manufacturer Part Number BPR122022000 Voltage 12/24 Peak Current (During 30 Seconds) 600A Max. Continuous Load Current 200A Connection M8 IP Rating Electronics: IP67 (potted) Connections: IP00 Dimensions (Including Terminals) H62 x 123 x D120 Weight (kg) 0.8 Warranty 5 Years
£92.49 Exc. VAT
£110.99 Inc. VAT