Brand |
Victron Energy |
---|---|
Manufacturer Part Number |
CYR010120430 |
Voltage |
12/24 |
Continuous current & Breaking capacity at 12V or 24V |
120A |
Current Consumption When Open |
4 mA |
Protection Category |
IP54 |
Dimensions |
H46 x W46 x D80mm |
Weight (kg) |
0.11 |
Warranty |
5 Years |
![Victron](http://powerlandgenerators.myshopify.com/cdn/shop/files/Victron.png?v=1731072885&width=900)
Victron Energy Cyrix-Li-charge 12/24V 120A Intelligent Charge Relay – CYR010120430
Product form
In stock
Fast shipping
Collection available More info
Overview
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature.
In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay of 3 seconds. After two attempts to reengage with 3 seconds delay, the delay increases to 10 minutes.
Whenever battery voltage is less than 13,5V (resp. 27V or 54V), the Cyrix will disengage with a delay of 1 hour. Note 1: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected, because battery voltage will remain higher than 13,5V. Note 2: If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,7V or more, the Cyrix will re-engage, with 3 seconds delay